Wednesday, 31 January 2024
Daily statistics of the Spanish peninsular's electricity system
Definitive data to 10/12/2024 • 12:11:34
Daily energy balance (GWh) (1) | Day | Month | %∆ Month | Annual | %∆ Annual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Hydro | 160 | 3.928 | 1,8 | 3.928 | 1,8 | 25.405 | 29,1 |
Pumped storage (3) | 12 | 452 | -16,8 | 452 | -16,8 | 5.113 | 24,6 |
Nuclear | 170 | 5.161 | 1,5 | 5.161 | 1,5 | 54.350 | -2,9 |
Coal | 12 | 269 | -9,2 | 269 | -9,2 | 3.781 | -48,0 |
Combined cycle (4) | 113 | 2.758 | 25,8 | 2.758 | 25,8 | 39.848 | -30,8 |
Wind | 67 | 5.667 | -22,6 | 5.667 | -22,6 | 59.684 | -3,4 |
Solar PV | 85 | 1.884 | 10,6 | 1.884 | 10,6 | 36.928 | 34,3 |
Solar thermal | 6 | 94 | -21,1 | 94 | -21,1 | 4.671 | 14,7 |
Other renewables (5) | 11 | 283 | -2,7 | 283 | -2,7 | 3.579 | -20,7 |
Cogeneration (6) | 61 | 1.696 | 40,5 | 1.696 | 40,5 | 17.780 | 5,9 |
Non-renewables waste (7) | 4 | 99 | 4,1 | 99 | 4,1 | 1.189 | -29,9 |
Renewable waste (7) | 2 | 58 | -3,6 | 58 | -3,6 | 705 | -3,4 |
Generation | 703 | 22.350 | -1,9 | 22.350 | -1,9 | 253.033 | -3,3 |
Pumped storage consumption | -5 | -736 | -22,4 | -736 | -22,4 | -7.981 | 20,0 |
Balearic-Peninsula link (8) | -4 | -123 | -1,0 | -123 | -1,0 | -1.425 | 104,9 |
Exchange balance (9) | 7 | -489 | -47,0 | -489 | -47,0 | -13.523 | -30,8 |
Demand (b.c) | 700 | 21.002 | 1,0 | 21.002 | 1,0 | 230.104 | -2,0 |
Adjusted demand (10) | - | - | 1,2 | - | 1,2 | - | -1,4 |
Pérdidas en transporte | -17 | -465 | -9,1 | -465 | -9,1 | -4.772 | 3,0 |
Demand (distribution) | 683 | 20.537 | 1,3 | 20.537 | 1,3 | 225.332 | -2,1 |
Generation structure
31/01/2024
January
2024
Rolling year aggregate
-
No renewable:
- Coal
- Nuclear
- Pumped storage
- Combined cycle
- Non-renewables waste
- Cogeneration
-
Renewable:
- Other renewables
- Solar thermal
- Hydro
- Solar PV
- Renewable waste
- Wind
Renewable energy
Renewable energy (GWh) | Day | Month | %∆ Month | Annual | %∆ Anual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Total (11) | 330 | 11.914 | -10,8 | 11.914 | -10,8 | 130.971 | 10,7 |
Maximum demand
Maximum Demand | Day | Month | Year | Historical |
---|---|---|---|---|
Instantaneous Peak Load (MW) | 34.631 (20:53) | 38.272 (20:56 - 09/01) | 38.272 (20:56 - 09/01) | 45.450 (18:53 - 17/12/2007) |
Peak Load (MWh) | 34.378 (21h) | 38.086 (21h - 11/01) | 38.086 (21h - 11/01) | 44.876 (20h - 17/12/2007) |
Daily demand (GWh) | 700 | 772 (10/01) | 772 (10/01) | 906 (18/12/2007) |
Hydraulic data
Hydraulic data for 31 of january of 2024
Hydroelectric reserves (GWh) | Maximum capacity (A) | Today (B) | (B/A) % | Δ Day | 31/01/2023 (C) | (C/A) % | 01/01/2024 (D) | (D/A) % |
---|---|---|---|---|---|---|---|---|
Annual regime | 8.967 | 5.906 | 65,9 | -25 | 5.939 | 66,2 | 5.363 | 59,8 |
Hyperannual regime | 9.571 | 4.782 | 50,0 | -9 | 4.285 | 44,8 | 4.071 | 42,5 |
Total | 18.538 | 10.688 | 57,7 | -34 | 10.224 | 55,2 | 9.434 | 50,9 |
Producible hydroelectric energy | Day | Month | Index (month) | % P> (12) | Year | Index (year) | % P> (12) | Rolling year (2) | Index (rolling year) | % P> (12) |
---|---|---|---|---|---|---|---|---|---|---|
GWh | 126 | 5.170 | 1,4 | 15,5 | 5.170 | 1,4 | 15,5 | 25.870 | 0,9 | 59,4 |
- Note: All variance percentages shown refer to the same period in the previous year.
- (1) Allocation of production units according to primary fuel.
- (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
- (3) Pure pumped storage + mixed pumped storage estimate.
- (4) Includes operation in open cycle mode.
- (5) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
- (6) The increment and rolling year values include waste up to December 31, 2014.
- (7) Generation included in other renewables and cogeneration on 12/31/2014.
- (8) Positive value: incoming energy; negative value: outgoing energy.
- (9) Positive value: import balance; negative value: export balance
- (10) After factoring in the influence of seasonal and working patterns
- (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.
- (12) Percentage of probability of exceeding the index value.