Daily energy balance (GWh) (1) | Day | Month | %∆ Month | Annual | %∆ Annual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Hydro | 57 | 1.923 | -10,9 | 8.761 | -49,0 | 21.191 | -34,6 |
Pumped storage (3) | 6 | 300 | 25,7 | 1.411 | -2,3 | 2.616 | -8,9 |
Nuclear | 121 | 4.066 | -7,0 | 23.067 | 0,5 | 54.146 | -3,7 |
Coal | 22 | 528 | 58,6 | 3.205 | 102,6 | 6.562 | 79,2 |
Combined cycle (4) | 201 | 3.093 | 54,3 | 18.206 | 85,9 | 45.999 | 23,1 |
Wind | 50 | 4.571 | -1,1 | 26.502 | -3,4 | 58.267 | -2,0 |
Solar PV | 121 | 3.293 | 40,7 | 10.436 | 41,3 | 23.578 | 38,6 |
Solar thermal | 24 | 621 | -3,8 | 1.534 | 1,7 | 4.731 | -0,1 |
Other renewables (5) | 14 | 396 | 1,6 | 2.050 | 8,2 | 4.866 | 5,4 |
Cogeneration (6) | 63 | 1.869 | -15,2 | 10.051 | -7,6 | 25.220 | -6,5 |
Non-renewables waste (7) | 5 | 158 | -7,4 | 794 | -6,7 | 2.055 | 3,4 |
Renewable waste (7) | 2 | 67 | 27,3 | 340 | 16,8 | 800 | 18,6 |
Generation | 686 | 20.886 | 6,9 | 106.358 | 3,0 | 250.030 | 0,8 |
Pumped storage consumption | -4 | -443 | 12,6 | -2.331 | -5,8 | -4.174 | -10,5 |
Balearic-Peninsula link (8) | -1 | -32 | -71,3 | -155 | -74,3 | -443 | -70,5 |
Exchange balance (9) | -22 | -1.314 | - | -5.429 | - | -5.344 | - |
Demand (b.c) | 659 | 19.097 | -1,0 | 98.443 | -2,5 | 240.069 | -0,8 |
Adjusted demand (10) | - | - | -3,6 | - | -3,0 | - | -0,9 |
Pérdidas en transporte | -10 | -356 | 20,2 | -1.860 | -2,7 | -4.169 | -0,6 |
Demand (distribution) | 648 | 18.741 | -1,4 | 96.583 | -2,4 | 235.900 | -0,8 |
Generation structure
31/05/2022
May
2022
Rolling year aggregate
-
No renewable:
- Coal
- Nuclear
- Pumped storage
- Combined cycle
- Non-renewables waste
- Cogeneration
-
Renewable:
- Other renewables
- Solar thermal
- Hydro
- Solar PV
- Renewable waste
- Wind
Renewable energy
Renewable energy (GWh) | Day | Month | %∆ Month | Annual | %∆ Anual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Total (11) | 268 | 10.872 | 6,5 | 49.624 | -10,9 | 113.432 | -4,6 |
Maximum demand
Maximum Demand | Day | Month | Year | Historical |
---|---|---|---|---|
Instantaneous Peak Load (MW) | 30.850 (13:20) | 32.127 (13:48 - 20/05) | 37.926 (20:10 - 19/01) | 45.450 (18:53 - 17/12/2007) |
Peak Load (MWh) | 30.731 (14h) | 31.846 (14h - 19/05) | 37.785 (21h - 20/01) | 44.876 (20h - 17/12/2007) |
Daily demand (GWh) | 659 | 676 (19/05) | 773 (20/01) | 906 (18/12/2007) |
Hydraulic data
Hydraulic data for 31 of may of 2022
Hydroelectric reserves (GWh) | Maximum capacity (A) | Today (B) | (B/A) % | Δ Day | 31/05/2021 (C) | (C/A) % | 01/01/2022 (D) | (D/A) % |
---|---|---|---|---|---|---|---|---|
Annual regime | 8.967 | 5.005 | 55,8 | -9 | 6.063 | 67,6 | 3.952 | 44,1 |
Hyperannual regime | 9.571 | 2.858 | 29,9 | 1 | 5.051 | 52,8 | 2.777 | 29,0 |
Total | 18.538 | 7.863 | 42,4 | -8 | 11.114 | 60,0 | 6.729 | 36,3 |
Producible hydroelectric energy | Day | Month | Index (month) | % P> (12) | Year | Index (year) | % P> (12) | Rolling year (2) | Index (rolling year) | % P> (12) |
---|---|---|---|---|---|---|---|---|---|---|
GWh | 49 | 1.890 | 0,6 | 91,7 | 9.945 | 0,6 | 94,3 | 17.940 | 0,6 | 92,9 |
- Note: All variance percentages shown refer to the same period in the previous year.
- (1) Allocation of production units according to primary fuel.
- (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
- (3) Pure pumped storage + mixed pumped storage estimate.
- (4) Includes operation in open cycle mode.
- (5) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
- (6) The increment and rolling year values include waste up to December 31, 2014.
- (7) Generation included in other renewables and cogeneration on 12/31/2014.
- (8) Positive value: incoming energy; negative value: outgoing energy.
- (9) Positive value: import balance; negative value: export balance
- (10) After factoring in the influence of seasonal and working patterns
- (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.
- (12) Percentage of probability of exceeding the index value.