[x] Close [I] Print

Logotipo de Red Eléctrica de España

Sunday, 31 December 2023

Daily statistics of the national electricity system

Provisional data to 13/05/2024 • 19:37:20

Daily energy balance (GWh) (1) Day Month %∆ Month Annual %∆ Annual Rolling year (2) %∆ Rolling year
Hydro 70 3.984 44,8 25.330 41,4 25.330 41,4
Pumped storage (3) 19 445 -8,3 5.204 37,8 5.204 37,8
Nuclear 169 4.990 -3,3 54.276 -3,0 54.276 -3,0
Coal 6 212 -69,5 3.868 -50,2 3.868 -50,2
Fuel oil+gas 12 353 -5,1 4.483 1,6 4.483 1,6
Combined cycle (5) 80 3.193 -26,9 46.051 -32,4 46.051 -32,4
Hydrowind 0 1 82,3 17 -23,6 17 -23,6
Wind 235 5.836 4,6 62.650 2,4 62.650 2,4
Solar PV 37 1.876 65,8 37.468 34,3 37.468 34,3
Solar thermal 0 92 54,0 4.696 13,9 4.696 13,9
Other renewables (6) 5 255 -20,5 3.594 -22,9 3.594 -22,9
Cogeneration (7) 24 1.171 6,6 17.314 -2,5 17.314 -2,5
Non-renewables waste (8) 3 112 -16,9 1.319 -30,6 1.319 -30,6
Renewable waste (8) 3 75 2,0 846 -3,6 846 -3,6
Generation 665 22.595 1,6 267.117 -3,3 267.117 -3,3
Pumped storage consumption -62 -683 -17,3 -8.193 34,4 -8.193 34,4
Exchange balance (9) -2 -770 -31,1 -13.957 -29,5 -13.957 -29,5
Demand (b.c) 601 21.142 4,2 244.967 -2,2 244.967 -2,2
Adjusted demand (10) - - 3,9 - -1,8 - -1,8
Transmission losses -19 -553 10,6 -5.228 9,9 -5.228 9,9
Demand (distribution) 582 20.589 4,0 239.739 -2,4 239.739 -2,4

Generation structure

31/12/2023
December
2023
Rolling year aggregate
  • No renewable:
    • Coal
    • Nuclear
    • Pumped storage
    • Combined cycle
    • Fuel oil+gas
    • Non-renewables waste
    • Cogeneration
  • Renewable:
    • Other renewables
    • Hydrowind
    • Solar thermal
    • Hydro
    • Solar PV
    • Renewable waste
    • Wind

Renewable energy

Renewable energy (GWh) Day Month %∆ Month Annual %∆ Annual Rolling year (2) %∆ Rolling year
Total (11) 350 12.119 22,2 134.601 15,3 134.601 15,3
  • Note: All variance percentages shown refer to the same period in the previous year.
  • (1) Allocation of production units according to primary fuel.
  • (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
  • (3) Pure pumped storage + mixed pumped storage estimate.
  • (4) Generation from auxiliary generators is included in the electricity systems of the Balearic Islands.
  • (5) Includes operation in open cycle mode. Power generation for the electricity system of the Canary Islands’ electricity system is obtained primarily from gas-oil.
  • (6) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
  • (7) Generation included in other renewables and cogeneration on 12/31/2014.
  • (8) Generation included in other renewables and cogeneration up to December 31, 2014.
  • (9) Positive value: import balance; negative value: export balance
  • (10) After factoring in the influence of seasonal and working patterns
  • (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.