Logotipo de Red Eléctrica de España

Friday, 31 December 2021

Daily statistics of the national electricity system

Definitive data to 10/11/2022 • 19:59:35

Daily energy balance (GWh) (1) Day Month %∆ Month Annual %∆ Annual Rolling year (2) %∆ Rolling year
Hydro 68 2.537 -20,5 29.626 -3,3 29.626 -3,3
Pumped storage (3) 17 270 -15,9 2.649 -3,7 2.649 -3,7
Nuclear 146 3.923 -25,6 54.041 -3,1 54.041 -3,1
Coal 27 720 139,9 4.983 -0,7 4.983 -0,7
Fuel oil+gas 12 358 5,4 4.049 -3,4 4.049 -3,4
Combined cycle (5) 52 5.154 69,6 44.500 1,1 44.500 1,1
Hydrowind 0 1 28,1 23 18,2 23 18,2
Wind 121 6.910 -7,1 60.526 10,2 60.526 10,2
Solar PV 48 1.024 37,8 20.981 37,1 20.981 37,1
Solar thermal 7 104 36,4 4.706 3,7 4.706 3,7
Other renewables (6) 14 436 3,2 4.720 5,3 4.720 5,3
Cogeneration (7) 52 2.175 -7,7 26.091 -3,5 26.091 -3,5
Non-renewables waste (8) 6 181 -4,5 2.239 11,0 2.239 11,0
Renewable waste (8) 3 82 8,8 878 21,0 878 21,0
Generation 574 23.875 0,5 260.011 3,4 260.011 3,4
Pumped storage consumption -31 -522 -1,2 -4.318 -6,7 -4.318 -6,7
Exchange balance (9) 68 -1.324 65,4 852 -74,0 852 -74,0
Demand (b.c) 611 22.030 -1,8 256.546 2,6 256.546 2,6
Adjusted demand (10) - - -1,3 - 2,5 - 2,5
Pérdidas en transporte -15 -441 -0,6 -4.441 7,6 -4.441 7,6
Demand (distribution) 596 21.589 -1,8 252.105 2,5 252.105 2,5

Generation structure

31/12/2021
December
2021
Rolling year aggregate
  • No renewable:
    • Coal
    • Nuclear
    • Pumped storage
    • Combined cycle
    • Fuel oil+gas
    • Non-renewables waste
    • Cogeneration
  • Renewable:
    • Other renewables
    • Hydrowind
    • Solar thermal
    • Hydro
    • Solar PV
    • Renewable waste
    • Wind

Renewable energy

Renewable energy (GWh) Day Month %∆ Month Annual %∆ Anual Rolling year (2) %∆ Rolling year
Total (11) 262 11.094 -7,2 121.459 9,8 121.459 9,8
  • Note: All variance percentages shown refer to the same period in the previous year.
  • (1) Allocation of production units according to primary fuel.
  • (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
  • (3) Pure pumped storage + mixed pumped storage estimate.
  • (4) Generation from auxiliary generators is included in the electricity systems of the Balearic Islands.
  • (5) Includes operation in open cycle mode. Power generation for the electricity system of the Canary Islands’ electricity system is obtained primarily from gas-oil.
  • (6) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
  • (7) Generation included in other renewables and cogeneration on 12/31/2014.
  • (8) Generation included in other renewables and cogeneration up to December 31, 2014.
  • (9) Positive value: import balance; negative value: export balance
  • (10) After factoring in the influence of seasonal and working patterns
  • (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.