Wednesday, 30 September 2020
Daily statistics of the national electricity system
Definitive data to 10/11/2021 • 11:10:04
Daily energy balance (GWh) (1) | Day | Month | %∆ Month | Annual | %∆ Annual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Hydro | 58 | 1.672 | 36,4 | 23.070 | 41,6 | 31.495 | 40,6 |
Pumped storage (3) | 10 | 188 | 80,0 | 1.991 | 92,3 | 2.601 | 71,9 |
Nuclear | 167 | 4.871 | -2,5 | 41.318 | -5,1 | 53.626 | -5,6 |
Coal | 13 | 351 | -48,6 | 4.061 | -61,7 | 6.116 | -71,1 |
Fuel oil+gas | 12 | 347 | -28,5 | 3.148 | -27,8 | 4.483 | -24,7 |
Combined cycle (5) | 197 | 4.979 | -13,3 | 34.101 | -18,6 | 47.427 | -7,9 |
Hydrowind | 0 | 2 | -13,8 | 16 | -11,4 | 21 | 0,2 |
Wind | 66 | 4.055 | 4,1 | 37.483 | 0,0 | 54.229 | 6,9 |
Solar PV | 45 | 1.460 | 69,5 | 12.430 | 67,7 | 14.269 | 62,3 |
Solar thermal | 7 | 452 | -0,6 | 4.014 | -15,0 | 4.456 | -14,4 |
Other renewables (6) | 12 | 396 | 31,2 | 3.249 | 20,5 | 4.171 | 16,2 |
Cogeneration (7) | 79 | 2.310 | -2,0 | 19.927 | -10,6 | 27.241 | -8,7 |
Non-renewables waste (8) | 6 | 189 | -6,6 | 1.469 | -14,1 | 1.982 | -14,9 |
Renewable waste (8) | 2 | 73 | -5,6 | 497 | -25,1 | 723 | -19,4 |
Generation | 673 | 21.346 | -0,2 | 186.775 | -4,1 | 252.840 | -3,0 |
Pumped storage consumption | 0 | -222 | 17,7 | -3.437 | 91,6 | -4.670 | 81,0 |
Exchange balance (9) | 18 | -626 | - | 2.881 | -53,0 | 3.613 | -47,9 |
Demand (b.c) | 691 | 20.499 | -3,8 | 186.220 | -6,5 | 251.783 | -5,0 |
Adjusted demand (10) | - | - | -5,0 | - | -6,8 | - | -5,4 |
Pérdidas en transporte | -10 | -325 | 2,1 | -2.986 | 8,1 | -4.148 | 8,2 |
Demand (distribution) | 681 | 20.174 | -3,8 | 183.234 | -6,7 | 247.635 | -5,2 |
Generation structure
30/09/2020
September
2020
Rolling year aggregate
-
No renewable:
- Coal
- Nuclear
- Pumped storage
- Combined cycle
- Fuel oil+gas
- Non-renewables waste
- Cogeneration
-
Renewable:
- Other renewables
- Hydrowind
- Solar thermal
- Hydro
- Solar PV
- Renewable waste
- Wind
Renewable energy
Renewable energy (GWh) | Day | Month | %∆ Month | Annual | %∆ Anual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Total (11) | 189 | 8.111 | 18,9 | 80.760 | 16,5 | 109.364 | 19,3 |
- Note: All variance percentages shown refer to the same period in the previous year.
- (1) Allocation of production units according to primary fuel.
- (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
- (3) Pure pumped storage + mixed pumped storage estimate.
- (4) Generation from auxiliary generators is included in the electricity systems of the Balearic Islands.
- (5) Includes operation in open cycle mode. Power generation for the electricity system of the Canary Islands’ electricity system is obtained primarily from gas-oil.
- (6) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
- (7) Generation included in other renewables and cogeneration on 12/31/2014.
- (8) Generation included in other renewables and cogeneration up to December 31, 2014.
- (9) Positive value: import balance; negative value: export balance
- (10) After factoring in the influence of seasonal and working patterns
- (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.