Logotipo de Red Eléctrica de España

Tuesday, 30 April 2024

Daily statistics of the Balearic Islands' electricity system

Provisional data to 10/12/2024 • 12:15:29

Daily energy balance (MWh) (1) Day Month %∆ Month Annual %∆ Annual Rolling year (2) %∆ Rolling year
Coal -36 -939 - -3.018 - 60.035 -23,6
Motores diesel 141 18.212 155,3 33.761 1,1 251.792 -18,9
Gas turbine 1.899 29.499 0,2 103.390 -29,0 455.875 -5,4
Fuel oil+gas 2.040 47.711 30,4 137.151 -23,4 707.666 -10,7
Combined cycle (3) 7.416 205.682 -1,0 881.743 -5,0 3.025.112 -16,6
Auxiliary generation (4) 0 0 - 0 - 0 -
Wind 0 0 - 0 - 541 -53,1
Solar PV 877 44.587 14,6 144.894 25,2 419.670 32,5
Other renewables (5) 0 16 -84,1 199 -62,1 1.237 -9,2
Cogeneration (6) 131 1.910 -46,9 13.071 -0,6 36.891 36,0
Non-renewables waste (7) 333 11.323 6,2 40.246 7,4 135.894 -1,4
Renewable waste (7) 333 11.323 6,2 40.246 7,4 135.894 -1,4
Generation 11.093 321.613 4,5 1.254.533 -4,2 4.522.942 -11,9
Balearic-Peninsula link (8) 4.758 109.362 11,6 457.534 16,2 1.489.682 70,5
Demand (b.c) 15.851 430.975 6,2 1.712.067 0,5 6.012.624 0,1
Adjusted demand (9) - - 5,0 - 4,0 - 0,3
Transmission losses -349 -8.913 4,3 -37.447 5,8 -128.126 12,4
Demand (distribution) 15.502 422.062 6,3 1.674.620 0,4 5.884.498 -0,1

Generation structure

30/04/2024
April
2024
Rolling year aggregate
  • No renewable:
    • Coal
    • Diesel engines
    • Gas turbine
    • Auxiliary generation
    • Combined cycle
    • Non-renewables waste
    • Cogeneration
  • Renewable:
    • Wind
    • Renewable waste
    • Solar PV
    • Other renewables

Renewable energy

Renewable energy (GWh) Day Month %∆ Month Annual %∆ Anual Rolling year (2) %∆ Rolling year
Total (10) 1.210 55.926 12,3 185.340 20,0 557.343 21,9

Maximum demand

Maximum Demand Day Month Year Historical
Peak Load (MWh) 805 (22h) 884 (21h - 22/04) 908 (21h - 11/01) 1.496 (20h - 08/11/2007)
Daily demand (MWh) - 16.504 (23/04) 16.556 (11/01) 27.499 (03/08/2017)
  • Note: All variance percentages shown refer to the same period in the previous year.
  • (1) Allocation of production units according to primary fuel.
  • (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
  • (3) Includes operation in open cycle mode.
  • (4) Emergency generator units installed temporarily in specific zones to cover a deficit in generation.
  • (5) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
  • (6) The increment and rolling year values include waste up to December 31, 2014.
  • (7) Generation included in other renewables and cogeneration on 12/31/2014.
  • (8) Positive value: incoming energy; negative value: outgoing energy.
  • (9) After factoring in the influence of seasonal and working patterns.
  • (10) Includes wind, solar photovoltaic, other renewables and renewable waste.